TM 9-2350-287-20-2
15-42. FUEL FILL DOOR REPLACEMENT (continued).
c.
1.
2.
d.
1.
2.
3.
e.
1.
2.
CLEANING AND INSPECTION
Drycleaning solvent P-D-680 is toxic and flammable. Always wear protective goggles
and gloves, and use only in a well-ventilated area. Avoid contact with skin, eyes, and
clothes, and DO NOT use near open flame or excessive heat.
Clean all parts with drycleaning solvent, and
wipe dry with rags.
Inspect all parts for excessive wear, cracks,
or distortions. Replace damaged parts.
ASSEMBLY
Install two spacer plates (18 and 19) and rim
lock (11 ) on fuel fill door (17) with two new
Iockwashers (20) and two screws (21).
Install four nuts (9), new Iockwashers (10),
and four screws (13) on rim lock (11) and fuel
fill door (17).
Install pull handle (14) on fuel fill door (17)
with four new Iockwashers (16) and four
screws (15).
INSTALLATION
Install washers (3) and striker (2) on hull with
two screws (1).
Install fuel fill door (17) and four bronze
bearings (12) on hull-mounted bracket (6)
with nut (8), two washers (5), new lockwasher
(7), and screw (4).
FOLLOW-ON MAINTENANCE:
Close fuel fill door (refer to TM 9-2350-287-10).
15-103
|