TM 9-2350-287-20-2
15-39. APU COMPARTMENT ACCESS PLATE AND CAP ASSEMBLY REPLACEMENT
(continued).
b.
CLEANING AND INSPECTION
1.
Scrape gasket (1) from access plate (2).
2.
c.
1.
2.
3.
4.
5.
6.
7.
8.
WARNING
Drycleaning solvent PD-680 is toxic and flammable. Always wear protective goggles
and gloves, and use only in a well-ventilated area. Avoid contact with skin, eyes, and
clothes, and DO NOT breathe vapors. DO NOT use near open flame or excessive heat.
Thoroughly clean all adhesive residue from access plate surface with drycleaning solvent. Allow to air-dry.
INSTALLATION
Install ring (9) to fitting (7) by twisting and
connect ring (10) to one end of chain (8).
Secure cap assembly (5) to chain (8) with
screw (6), new lockwasher (9), and nut (11).
Position hose clamp (12) on cap assembly (5).
Press cap assembly (5) on connector (13) on
bulkhead.
Tighten hose clamp (12) on cap assembly (5).
WARNING
Adhesive solvent can burn easily, can give
off harmful vapors, and are harmful to skin
and clothing. To avoid injury or death,
keep away from open fire and use in well-
ventilated area.
If adhesive, solvent or
sealing compound gets on skin or clothing,
wash immediately with soap and water.
Add thin coating of rubber adhesive to new
gasket (1). Allow adhesive to dry until tacky.
install new gasket (1 ) against mounting surface
of APU access plate (2). Apply pressure to all
surfaces of gasket (1).
Install access plate (2) with new gasket (1) on
APU compartment with 10 screws (4) and new
Iockwashers (3).
FOLLOW-ON MAINTENANCE:
• Move left projectile rack assembly to front
of vehicle (refer to TM 9-2350-287-10).
15-98
|