TM 9-2350-287-20-12-19. TROUBLESHOOTING CHART (continued).g. GAGES (continued)(5) FUEL GAGE FAILS TO INDICATE A LEVEL READ-ING WITH BOTH FUEL TANKS FULL. All othergages operate propertyInitial Setup:Tools/Test Equipment:• Digital (DMM) muitimeter (Item 13, Appendix 1)• General mechanic’s tool kit (Item 24,Appendix 1)Materials/Parts:• Wire (Item 77, Appendix D)• LockWasher (3) (Item 175, Appendix H)• Self-locking nut (2) (Item 317, Appendix H)Personnel Required: TwoEquipment Conditions:• Fuel tanks full (refer to TM 9-2350-287-10).• MASTER switch set to OFF (refer toTM 9-2350-287-10).• Engine compartment heat shield removed(refer to TM 9-2350-287-10).• Driver’s portable instrument panel stowed inoutside position (refer to TM 9-2350-287-10).• Air intake grille open (refer toTM 9-2350-287-10).NOTE• Instead of using multi meterfor voltagecheck, STE/lCEtroubleshooting,INDIVIDUALBATTERY VOLTAGE TEST-TEST89 maybe performed.• Instead of using multi meterfor continuity check, STE/lCEtroubleshooting, TEST 91 maybe performed.A. 1. Remove four screws and driver’s portableinstrument panel cover plate.2. Disconnect harness 12260298 lead 28 fromfuel gage connector.3. Place red lead of multimeter in lead 28connector socket and ground black lead.4. Turn MASTER switch ON (refer to TM 9-2350-287-1O).5. Check for 24 ± 3 vdc.6. Turn MASTER switch OFF (refer to TM 9-2350-287-1O).Is voltage indicated?Repair lead 28 or replace harness 12260298(para 7-7). Verify problem is solved.Continued on next page2-115