TM 9-2350-287-10
- KEY -
Expected Temperatures
Lubricants
Intervals
Above 15° F
+40°Fto-10°F
+40°Fto-65°F
(Above -9°C)
(+4°C to -260C)
(+40C to -54°C)
OE / HDO
Intervals are as
(MIL-L-2104D)
follows:
LUBRICATING OIL,
M -Monthly
Internal Combustion
S - Semiannually
Engine
Intervals are based
Tactical Service
on normal hours of
operation and mod
erate operating
OEA
conditions.
(MIL-L-46167)
LUBRICATING OIL,
Internal Combus-
tion Engine, Arctic
OE/HDO
OE/HDO
Final Drive
15/W40
151W40
OEA
NOTES:
15. FINAL DRIVE LEVEL CHECK. Remove level check
plug (29). Oil should be level with bottom of opening. If
not, add oil until it flows from the plug opening (see key
for required oil type). Clean and install level-check plug
(29).
16. FINAL DRIVE DRAIN AND REFILL.
After operation, remove both level-check plugs (29) and
both drain plugs (30). Clean drain plugs (30); apply
teflon tape on drain plugs (30), and install drain plugs.
Add oil at level-check plug opening (see key for required
oil type). Clean, apply teflon tape, and install level-check
plugs (29).
NOTE
Notify Unit maintenance if you find pieces of metal stuck
to the magnetic drain plugs.
E-19