TM 9-2350-277-34
REPAIR POWER CONTROL ENCLOSURE, RIGHT PANEL (M1068A3 ONLY) Continued
0092 00
14. Remove circuit leads 22A, 21A, 3AA, 18C, and 27A (1) from ground fault interrupter (2). Remove two screws (3),
lockwashers (4), and ground fault interrupter (2) from enclosure (5). Discard lockwashers.
NOTE
See wiring diagram to disconnect wires from terminal blocks. There are set screws securing
each wire.
15. Remove all wiring from terminal blocks (6) by loosening all set screws. Remove four screws (7), locknuts (8), eight
washers (9), and two terminal blocks (6) from enclosure (5). Discard locknuts.
0092 00-5