TM 9-2350-277-34INSTALL ENGINE COOLANT HEATER KIT (M113A3, M901A3, AND M1059A3 ONLY) —Continued0075 00106. Open fuel tank shutoff valves (1).FOLLOW-THROUGH STEPS1. Lower power plant grille (see your -20).2. Fill carrier cooling system (see your -20).3. Connect battery ground lead (see your -20).4. Bleed coolant heater fuel line (see your -20).5. Start coolant heater (see your -10). Check that heater works right and does not leak. Turn coolant heater off.6. Install rear and right front floor plates (see your -20).7. Install driver’s compartment floor plates (see your -20)8. Install driver’s power plant access panel (see your -20).9. Install power plant rear access panel (see your -20).10. Close power plant front access door (see your -20).11. Raise trim vane (see your -10).END OF TASK0075 00-25/26 blank