1.
Remove pin (1) from strap (2).
2.
Loosen retaining strap (2) and remove fire extinguisher (3).
3.
Remove four screws (4) and four washers (5) securing mount (6) to hull.
4.
Remove screw (7), washer (8), locknut (9), and lanyard (10) with pin (1) from strap (2). Discard locknut.