TM 9-2350-277-20-6REPLACE APIU RACK MOUNT AND BRACKET (M1068A3 ONLY) 0813 00THIS WORK PACKAGE COVERS:Removal (page 0813 00-1).Installation (page 0813 00-2).INITIAL SETUP:Maintenance LevelUnitTools and Special ToolsGeneral Mechanic’s Tool Kit (WP 0926 00, Item 65)Materials/PartsLocknut (15)Personnel RequiredUnit MechanicReferencesSee your -10TM 11-7010-256-12&PEquipment ConditionEngine stopped (see your -10)Carrier blocked (see your -10)All external power disconnectedElectronic communication equipmentremoved (TM 11-7010-256-12)Curbside data panel assembly A12 removed(WP 0819 00)Battery ground lead disconnected (WP 0338 00)REMOVAL1. Remove four locknuts (1), screws (2), and receptacle (3) from bracket (4). Discard locknuts.2. Remove two screws (5), locknuts (6), four washers (7), clamp (8), and bracket (4) from APIU rack (9). Discard locknuts.3. Remove four screws (10), washers (11), locknuts (12), and mount (13) from APIU rack (9). Discard locknuts.0813 00-1