TM 9-2350-277-20-6REPLACE STE/ICE SHUNT (M113A3, M901A3, AND M1059A3 ONLY) — Continued 0870 004. Install lead 770 (13), new lockwasher (14), and screw (15) on shunt (5).5. Remove tape from battery lead (16) and install lead on shunt (5). Secure with two screws (17) and new lockwashers (18).6. Install battery ground strap (19), new lockwasher (20), and screw (21) to shunt (5).FOLLOW-THROUGH STEPS1. Connect battery ground strap (WP 0337 00).2. Install shunt guard (WP 0868 00).3. Close spall liners (see your -10).END OF TASK0870 00-5/6 blank