TM 9-2350-277-20-6REPLACE AC POWER EXTENSION CABLE (W8) (M1068A3 ONLY) 0843 00THIS WORK PACKAGE COVERS:Removal (page 0843 00-1).Installation (page 0843 00-2).INITIAL SETUP:Maintenance LevelUnitTools and Special ToolsGeneral Mechanic’s Tool Kit (WP 0926 00, Item 65)Materials/PartsStrap (16)Personnel RequiredPower-Generation Equipment Repairer 52D10ReferencesSee your -10TM 11-7010-256-12&PEquipment ConditionEngine stopped (see your -10)Carrier blocked (see your -10)All external power disconnected(TM 11-7010-256-12&P)Battery ground lead disconnected (WP 0338 00)REMOVAL1. Disconnect cable W8 plug P11 (1) from power control box A1 jack J31 (2).2. Remove and discard 16 plastic straps (3).3. Remove five screws (4) and loop clamps (5).4. Remove screw (6) and loop clamp (7).5. Disconnect cable W8 plug P1 (8) from curbside power box A7 jack J1 (9).0843 00-1