TM 9-2350-277-20-5REPLACE M8A3/M14 ORIFICE CONNECTOR ASSEMBLY, SUPPORT, AND QUICKCOUPLING HALF (M113A3, M1059A3, AND M577A3 ONLY) — Continued0780 00INSTALLATION1. Install two screws (10), new lockwashers (11), and support (9) on bulkhead.2. Install screw (7), new lockwasher (8), and mounting bracket (6) on support (9).3. Install orifice connector assembly (2) into mounting bracket (6). Secure with retaining ring (5).4. Assemble quick coupling half (4), hose (1), and clamp (3).5. Install hose (1) on orifice connector assembly (2).FOLLOW-THROUGH STEPS1. Raise and secure ramp (see your -10).END OF TASK0780 00-4