REPLACE ARTILLERY COMMUNICATION INSIDE CABLE (M577A3 ONLY)
0746 00
THIS WORK PACKAGE COVERS:
Removal (page 0746 00-1).
Installation (page 0746 00-2).
INITIAL SETUP:
Maintenance Level
Unit
Tools and Special Tools
General Mechanic’s Tool Kit (WP 0926 00, Item 65)
Personnel Required
Unit Mechanic
References
See your -10
E
quipment
Condition
Engine stopped (see your -10)
Carrier blocked (see your -10)
Ramp lowered (see your -10)
Battery ground lead disconnected (WP 0338 00)
REMOVAL
1.
Disconnect inside cable assembly (1) from artillery controls terminal board.
2.
Remove retainer (2) from cable assembly connector (3).
3.
Remove adapter (4) and cable assembly (1) from hull left rear plate threaded opening.
0746 00-1