TM 9-2350-277-20-5REPAIR COOLANT HEATER CONTROL BOX — Continued 0737 00ASSEMBLYNOTEBefore connecting electrical leads, check tags and wiring diagram below to verify properconnection.NOTEMake sure key in receptacle is at the top.1. Install receptacle in control box:a. Install receptacle (13) in control box (14). Secure with four new lockwashers (12) and screws (11).b. Install lead 17-D (9) on circuit breaker (10). Secure with lockwasher (8) and screw (7).c. Install lead 12-B (17) on HI-LO switch (18). Secure with lockwasher (16) and screw (15).d. Install lead 19-E (5), lead 20-C (4), and lead 14-A (3) on RUN-OFF-START switch (6). Secure with threelockwashers (2) and screws (1).0737 00-7