TM 9-2350-277-20-4REPLACE COMMANDER’S CUPOLA VISION BLOCK LOCKS AND SEALS (M1064A3ONLY) — Continued0491 00INSTALLATIONNOTESurface on seal marked BOND THIS SIDE should be glued to cupola.1. Apply adhesive to cleaned mating surface around vision block opening. Allow adhesive to become tacky. Install newseal (8) on cupola.2. Install washer (7) and post (6) in cupola. TIGHTEN POST TO 54-59 LB-FT (73-80 N m) TORQUE.3. Install periscope clamp (3) on post (6). Secure with washer (5) and bolt (4). TIGHTEN BOLT TO 144-168 LB-IN(16-19 N m) TORQUE.4. Install spring (2) and thumbscrew (1) on periscope clamp (3). Deform first thread of thumbscrew to prevent easyremoval.FOLLOW-THROUGH STEPS1. Install vision block (see your -10).END OF TASK0491 00-3/4 blank