TM 9-2350-277-20-4
REPLACE TURBINE ACCESS DOOR HINGES (M58 ONLY) Continued
0487 00
REMOVAL
WARNING
Do not remove screws securing door to hull. It may fall and injure personnel. Tag door handle
to warn those who want access to turbine compartment.
1.
Remove eight screws (1), washers (2), and two hinges (3) from carrier and turbine access door (4).
2.
Remove two cotter pins (5), shoulder pins (6), and washers (7) from four hinge halves (8). Discard cotter pins.
INSTALLATION
1.
Assemble four hinge halves (8) and install two shoulder pins (6), washers (7), and new cotter pins (5).
2.
Apply sealing compound to screws before installing in hinges.
3.
Install two hinges (3), eight washers (2), and screws (1) on turbine access door (4) and carrier.
END OF TASK