TM 9-2350-277-20-4REPLACE HULL DRAIN PLUG 0451 00THIS WORK PACKAGE COVERS:Removal (page 0451 00-1).Installation (page 0451 00-2).INITIAL SETUP:Maintenance LevelUnitTools and Special ToolsGeneral Mechanic’s Tool Kit (WP 0926 00, Item 65)Personnel RequiredUnit MechanicReferencesSee your -10Equipment ConditionEngine stopped (see your -10)Carrier blocked (see your -10)Rear floor plates removed (see Table of Contents)REMOVALCAUTIONCarrier should not be operated with hull drain plug removed. This reduces air flow throughradiator and draws dirt and debris into power plant compartment.1. Remove nut (1) from screw (2).2. Remove screw (2) and washer (3) from plug (4).3. Remove plug (4) from hull.0451 00-1