TM 9-2350-277-20-3
REPLACE BATTERY LEADS AND TERMINALS (M577A3 AND M1068A3
ONLY)
0341 00
THIS WORK PACKAGE COVERS:
Removal (page 0341 00-1).
Cleaning and Inspection (page 0341 00-3).
Installation (page 0341 00-4).
INITIAL SETUP:
Maintenance Level
Unit
Tools and Special Tools
General Mechanics Tool Kit (WP 0926 00, Item 65)
Battery Wire Brush (WP 0926 00, Item 10)
Battery Terminal Puller (WP 0926 00, Item 37)
Materials/Parts
Grease (WP 0928 00, Item 12)
Sodium bicarbonate (WP 0928 00, Item 60)
Grommet (2)
Personnel Required
Unit Mechanic
References
See your -10
Equipment Condition
Engine stopped (see your -10)
Carrier blocked (see your -10)
Ramp lowered (see your -10)
Battery access cover removed (see your -10)
Battery ground lead disconnected (WP 0338 00)
Personnel heater removed (for STE/ICE shunt leads
only) (WP 0703 00)
REMOVAL
WARNING
Electrical current can burn you. Disconnect ground lead before starting task.
1.
Remove screw (1), washer (2), and ground lead (3) from shunt (4).
0341 00-1