TM 9-2350-277-20-2
PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS), INCLUDING
LUBRICATION INSTRUCTIONS Continued
0155 00
ITEM
NO.
INTERVAL
MAN-
HOUR
ITEM TO BE
CHECKED OR
SERVICED
CREWMEMBER
PROCEDURE
EQUIPMENT
NOT READY/
AVAILABLE
IF:
d. ON CONDITION Drain transmission oil.
WARNING
Hot parts can burn you. Use care whenc
you work near hot power unit.
NOTE
Drain oil (36 quarts) only when hot after
operation. Allow oil to drain for 1 hour if
time permits.
1) Remove access cover from bottom of hull
(WP 0450 00).
2) Place a suitable container under
transmission drain tube.
3) Remove plug from drain tube and drain oil
into container.
4) Inspect plug and oil for metallic particles. If
metal chips are found, notify direct support
maintenance.
0155 00-48