TM 9-2350-277-20-2PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS), INCLUDINGLUBRICATION INSTRUCTIONS — Continued0155 00ITEMNO.INTERVALMAN-HOURITEM TO BECHECKED ORSERVICEDCREWMEMBERPROCEDUREEQUIPMENTNOT READY/AVAILABLEIF:d. ON CONDITION — Drain transmission oil.WARNINGHot parts can burn you. Use care whencyou work near hot power unit.NOTEDrain oil (36 quarts) only when hot afteroperation. Allow oil to drain for 1 hour iftime permits.1) Remove access cover from bottom of hull(WP 0450 00).2) Place a suitable container undertransmission drain tube.3) Remove plug from drain tube and drain oilinto container.4) Inspect plug and oil for metallic particles. Ifmetal chips are found, notify direct supportmaintenance.0155 00-48