TM 9-2350-277-20-2
SERVICE AIR CLEANER FILTER ELEMENT Continued
0167 00
2.
Wash element in solution of nonsudsing or low sudsing detergent and water or soap and water. Do not use gasoline or
solvents for cleaning.
a.
Prepare solution of 1 cup of dry detergent to 5 gallons of water in a container large enough to completely submerge
the element. The temperature of the solution should not exceed 190
F (88
C). Make solution stronger if element is
extremely dirty.
b.
Immerse element completely in the washing solution. Agitate element gently for 2 minutes.
c.
Allow element to soak in solution for a minimum of 15 minutes. Agitate element gently for an additional 3 to 5
minutes.
d.
Remove element from solution and allow to drain.
e.
Rinse element with cold water from a hose with a maximum 45 psi (310 kpa) water pressure from inside to outside
of element. Continue rinsing until water runs clear and detergent or soap residue is removed from element.
f.
Allow element to air dry thoroughly.
FOLLOW-THROUGH STEPS
1.
Install air cleaner element (see your -10).
END OF TASK
0167 00-2