TM 9-2350-277-20-1
STE/ICE TEST 30 TURBOCHARGER OUTLET PRESSURE DIAGNOSTIC
TROUBLESHOOTINGContinued
0146 00
3Y
1. Remove harness 12354593 P1(1) from STE/ICE distribution box
jack J1 (2).
2. Set up Test 92 TM 9-4910-571-12&P.
3. Measure resistance between STE/ICE distribution box jack J2 (3),
pin AB (4) and the following jack pins:
a.
STE/ICE distribution box jack J2 (3) pin f (5)
b.
STE/ICE distribution box jack J2 (3) pin g (6)
c.
STE/ICE distribution box jack J1 (2) pin a (7)
d.
STE/ICE distribution box jack J1 (2) pin b (8)
4. Does VTM read between 3600 and 4400 ohms for each
measurement?
YES
NO
3YN
1. Replace STE/ICE distribution box
(WP 0874 00) thru (WP 0877 00).
2. Verify no faults found.
0146 00-3