TM 9-2350-277-20-1
NO POWER TO AC CIRCUITS (M1068A3 ONLY)
0107 00
INITIAL SETUP:
Maintenance Level
Unit
Tools and Special Tools
General Mechanics Tool Kit (WP 0926 00, Item 65)
Digital Multimeter (WP 0926 00, Item 30)
Materials/Parts
Lockwasher (10)
Personnel Required
Power-Generation Equipment Repairer 52D10
Helper (H)
References
See your -10
TM 11-7010-256-12&P
Equipment Condition
Engine stopped (see your -10)
Carrier blocked (see your -10)
WARNING
HIGH VOLTAGE is used in operation of this equipment.
DEATH ON CONTACT may result if personnel fail to observe safety precautions.
NEVER work on equipment unless at least one other person familiar with operation and
hazards of equipment is nearby. That person should also be familiar with giving first aid. When
an operator helps a mechanic, that operator must be warned about dangerous areas.
SHUT OFF POWER supply to equipment before beginning work. Make sure all external power
is OFF/disconnected.
BE CAREFUL not to touch high-voltage connections when installing or operating this
equipment.
0107 00-1