NO AC/DC INPUT TO ATCCS UPS POWER BOX (M1068A3 ONLY)Continued - TM-9-2350-277-20-1_483
NO AC/DC INPUT TO ATCCS UPS POWER BOX (M1068A3 ONLY)Continued - TM-9-2350-277-20-1_485
TM-9-2350-277-20-1 Hull Powerpack Drive Controls Tracks Suspension and Associated Components Carrier Ammunition Tracked Manual
Page Navigation
367
368
369
370
371
372
373
374
375
376
377
TM 9-2350-277-20-1
NO AC/DC INPUT TO ATCCS UPS POWER BOX (M1068A3 ONLY)—Continued
0100 00
2Y
1. Remove screw (1), lockwasher (2), and ground strap W12
terminal (3) from ground lug (4). Discard lockwasher.
2. Remove nut (5), lockwasher (6), and ground strap W12 terminal
(7) from ATCCS UPS storage box (8). Discard lockwasher.
3. Measure
resistance
between terminals (3) and (7) of ground strap
W12.
4. Does
multimeter
read 0 ohms?
YES
NO
2YN
1. Replace ground strap W12
(WP 0846 00).
2. Verify no faults found.