TM 9-2350-277-20-1
NO POWER FROM CURBSIDE AC POWER EXTENSION BOX A7 (M1068A3
ONLY)Continued
0094 00
BY
1. Turn MASTER POWER switch to OFF (see your -10) and TM
11-7010-256-12&P.
2. Remove ten screws (1) and lockwashers (2). Lower faceplate (3).
Discard lockwashers.
3. Turn ON AC RIGHT OUTLETS circuit breakers CB8 (4) and
CB9 (5).
4. Measure resistance between terminal 1 and terminal 2 (6) of
circuit breaker CB8 (4).
5. Measure resistance between terminal 1 and terminal 2 (6) of
circuit breaker CB9 (5).
6. Does multimeter read 0 ohms for each measurement?
YES
NO
BYN
1. Resistance in CB8 and CB9 should
be 0 ohms. If any resistance is
present, replace that CB
(WP 0828 00).
2. Verify no faults found.
B2Y
1. Raise faceplate and secure to Power Control Enclosure with ten
new lockwashers and screws.
2. Go to: No Power To AC Circuits (M1068A3 Only)
(WP 0107 00).
0094 00-4