TM 9-2350-277-20-1NO POWER FROM CURBSIDE AC POWER EXTENSION BOX A7 (M1068A3ONLY)—Continued0094 00BY1. Turn MASTER POWER switch to OFF (see your -10) and TM11-7010-256-12&P.2. Remove ten screws (1) and lockwashers (2). Lower faceplate (3).Discard lockwashers.3. Turn ON AC RIGHT OUTLETS circuit breakers CB8 (4) andCB9 (5).4. Measure resistance between terminal 1 and terminal 2 (6) ofcircuit breaker CB8 (4).5. Measure resistance between terminal 1 and terminal 2 (6) ofcircuit breaker CB9 (5).6. Does multimeter read 0 ohms for each measurement?YESNOBYN1. Resistance in CB8 and CB9 shouldbe 0 ohms. If any resistance ispresent, replace that CB(WP 0828 00).2. Verify no faults found.B2Y1. Raise faceplate and secure to Power Control Enclosure with tennew lockwashers and screws.2. Go to: No Power To AC Circuits (M1068A3 Only)(WP 0107 00).0094 00-4