SERVICE AND/OR BLACK OUT STOP LIGHTS MALFUNCTION
SERVICE AND/OR BLACK OUT STOP LIGHTS MALFUNCTIONContinued - TM-9-2350-277-20-1_199
TM-9-2350-277-20-1 Hull Powerpack Drive Controls Tracks Suspension and Associated Components Carrier Ammunition Tracked Manual
Page Navigation
120
121
122
123
124
125
126
127
128
129
130
TM 9-2350-277-20-1
SERVICE AND/OR BLACK OUT STOP LIGHTS MALFUNCTION—Continued
0033 00
3Y
1. Turn MASTER SWITCH to OFF.
2. Remove harness 12349881 circuit 75A plug (1) from switch jack
(2).
3. Remove harness 12349881 circuit 75B plug (3) from switch jack
(4).
4. Measure
resistance
between switch jacks (2) and (4) with switch
depressed and with switch released.
5. Does
multimeter
read infinity with switch depressed and 0 ohm
with switch released?
YES
NO
3YN
1. Replace brake light switch
(WP 0332 00).
2. Verify no faults found.
4Y
1. Install harness 12349881 circuit leads 75A and 75B on stop
sensitive switch.
2. Remove instrument panel for access (WP 0295 00).
3. Remove harness 12349881 plug (1) from lighting control switch
jack (2).
4. Measure
resistance
between harness 12349881 plug (1) pins K (3)
and A (4) with brake pedal depressed.
5. Does
multimeter
read less than 0 ohm?
YES
NO
4YN
1. Faulty harness 12349881 circuit 75A
and/or 75B. Beyond unit
maintenance repair.
2. Notify supervisor.
0033 00-2