TM 9-2350-277-20-1
ENGINE CRANKS BUT WONT START BELOW 40
F (GLOW PLUGS ARE
USED)
0023 00
INITIAL SETUP:
Maintenance Level
Unit
Tools and Special Tools
General Mechanics Tool Kit (WP 0926 00, Item 65)
Multimeter (WP 0926 00, Item 30)
Personnel Required
Unit Mechanic
References
See your -10
Equipment Condition
Engine stopped (see your -10)
Carrier blocked (see your -10)
T
1. Does engine crank at normal speed?
YES
NO
TN
1. Go to Engine Cranks Slowly
(WP 0020 00).
Y
1. Is engine temperature less than 50
F (11
C)?
YES
NO
YN
1. Go to Engine Cranks But Will Not
Start (WP 0021 00).
2Y
1. Turn MASTER SWITCH on (see your -10).
2. Momentarily turn GLOW PLUG switch (2) on.
3. Does WAIT indicator (1) come on?
YES
NO
2YN
1. Replace glow plug controller
(WP 0210 00).
2. Verify no faults found.
3Y
1. After 35 seconds, did WAIT indicator start flashing?
YES
NO
3YN
1. Replace glow plug controller
(WP 0210 00).
2. Verify no faults found.
0023 00-1