2-114TM 9-2350-267-20ARemove engine compartment access cover (p 3-14). Disconnectwire 415B from air cleaner blower pressure switch. TurnMASTER switch ON and use jumper wire to ground wire 415B.If blower motors operate, replace switch (p 6-10). If blowermotor fails to operate, go to step B.NOTETo trace circuit 415B check harnesses 12268102(p 6-64), 12268100 (p 6-68), 12260287 (p 6-84) and10897991 (p 6-92).B Disconnect wire 415B at air cleaner blower relay. Using jumper,ground wire 415B (lead from blower relay). If blower motorsoperate, replace wire 415B from air cleaner blower relay to aircleaner blower pressure switch. If motor fails to operate, go tostep c.TA310473
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business