BACKUP Hydraulic PUMP ASSEMBLY HOSES AND Connecting PARTS: REMOVAL AND INSTALLATION (CONTINUED)
REMOVAL
A
B
c
D
E
F
G
H
I
J
K
L
CAUTION
Take necessary precautions to prevent entry of
contaminants into hydraulic system. Hydraulic lines and
ports should be capped immediately after disconnecting
lines to avoid entry of contaminants into system.
Remove hose (1) from elbow (2).
Remove elbow (2) from pump inlet port (3).
Disconnect hose (1) from bulkhead quick-disconnect end (4).
Remove quick-disconnect end (5) from hose (1).
Remove hose (6) from clutch hydraulic port (7).
Disconnect hose (6) from bulkhead quick-disconnect end (8).
Remove quick-disconnect end (9) from hose (6).
Remove hose (10) from elbow (11).
Disconnect hose (10) from bulkhead quick-disconnect end (12).
Remove quick-disconnect end (13) from hose (10).
Remove quick-disconnect ends (4,8, and 12) from bushings (14 and 15) and
adapters.
Remove bushings (14 and 15) from adapters.
INSTALLATION
A
B
c
D
E
F
G
H
I
J
K
L
NOTE
Apply Teflon tape (item 62, Appx D) or Teflon pipe
sealant (item 57, Appx D) to all male threads during
installation.
Install bushings (14 and 15) in adapters.
Install quick-disconnect ends (4, 8 and 12) on bushings (14 and 15) and
adapters.
Install quick-disconnect end (13) on hose (10).
Connect hose (10) to bulk head quick-disconnect end (12).
Install hose (10) on elbow (11).
Install quick-disconnect end (9) on hose (6).
Connect hose (6) to bulkhead quick-disconnect end (8).
Install hose (6) on clutch hydraulic port (7).
Install quick-disconnect end (5) on hose (1).
Connect hose (1) to bulkhead quick-disconnect end (4).
Install elbow (2) in pump inlet port (3).
Install hose (1) on elbow (2).
16-22.7/(16-22.8 blank)
Change 4