TM 9-2350-267-10CHEMICAL AGENT DETECTION AND ALARM SYSTEM - ContinuedWhen used with the M992, the following instructions also apply.When vehicle is parked, connect detector unit (1) to vehicle hook-ups (2) viatelephone cable (3). Detector must then be operated by its own power supply (4).Detector may also be used inside cargo compartment during transit, although ef-fectiveness may be greatly reduced. For unit to operate in this situation, vehicleMASTER switch must be ON; detector and alarm system will then operate usingvehicle electrical power.During periods of continuous operation, detector unit’sfluid reservoir and air filter must be changed every 12hours. When operating less than 12 hours per day, reser-voir and filter must be changed daily. See TM 3-6665-225-12for complete instructions. Failure to observe this warningwill greatly reduce the effectiveness of the system.2-202