TM 9-2350-267-10OPERATING MAIN ENGINE AIR CLEANER SYSTEMSummer PositionNOTERight rack assembly must be movedbefore locking handles may be posi-tioned.In temperatures over 40° F, leave lockinghandles (1) in holders.In temperatures below 25o F, raise handles(1) and fasten them on hooks (2).Intermediate TemperaturesWhen operating in temperatures from 25° Fto 40° F, position as follows:1. Start engine with locking handles (1)in winter position.2. When engine reaches operating tem-perature, place handles in summerposition.AIR CLEANER RESTRICTION INDICATORAn air cleaner indicator gage (3) is located alongside hydraulic reservoir. It readsgreen when air cleaner is operating properly. When airflow is restricted, a redsleeve covers the green indicator indicating that air cleaner element should beservice (p 3-28). Reset button on air cleaner restriction indicator will retract redsleeve and green signal will show again. If restriction has not been removed, redsignal will return next time engine is operated.2-145