Home
Download PDF
Order CD-ROM
Order in Print
C H E M I C A L A G E N T A U T O A L A R M M A L F U N C T I O NS
C H E M I C A L A G E N T A U T O A L A R M M A L F U N C T I O NS ...CONT.
TM-9-2350-261-20-1 Carrier Personnel Full Tracked Armored M113A2 2350-01-068-4077 Carrier Command Post Light Tracked M577A2 2350-01-068-4089 Manual
Page Navigation
544
545
546
547
548
549
550
551
552
553
554
TM 9-2350-261-20-1
1. Measure voltage between terminal 6B (1) on
circuit breaker and ground.
2. Does
multimeter
read less than 17 volts?
YES
1. Remove battery box cover.
2. Remove 6B pos (+) and 7B neg (-) terminal from
battery post.
3. Measure
resistance
between 6B pos (+) (1) terminal
from battery and circuit breaker.
4. Measure
resistance
between 7B neg (-) (2) terminal
from battery and circuit breaker.
5. Does
multimeter
read 0 ohms for either measure-
ment?
1. Replace circuit breaker
(page 44-2).
2. Verify no faults found.
1. Replace cable assembly
11647667 (page 44-6).
2. Verify no faults found.
3-234
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business