TM 9-2350-261-20-1
1. Remove cable W43 plug P2 (1) from Roadside AC Power
Extension Box A6 jack J6 (2).
2. Apply AC power to SICPS system
(see TM 11-7010-256-12&P).
3. Set AC LEFT OUTLETS switches on Power Control
Enclosure panel to ON.
4. Measure voltage between sockets H and N of J6 (2).
5. Does multimeter read 110 volts AC or more?
3-226.52
Change 3
1. Go to: No Power From Road-
s i d e A C P o w e r E x t e n s i o n