TM9-2350-261-10
11. Push fuel cutoff control in.
12. Pull air ventilator control out.
1. Press HORN switch.
/
FUEL
CUTOFF
I
S T A R T E N G I N E ( A B O VE
+ 4 0 ° F ( + 4 ° C ) )
N O T E
I f t a c t i c a l s i t u a t i o n p e r m i t s ,
horn should be sounded to warn
personnel that engine is about to
be started.
Horn
SWITCH
C A U T I ON
Pressing START switch for more
than 15 seconds at temperatures
above +4°F can damage start-
er. Do not press START switch
for more than 15 seconds at a
time. If engine does not start on
first try, wait at least 30 seconds
AIR Ventilator
CONTROL
N O T E
See next column for procedure
t o s t a r t e n g i n e w h e n a ir
temperature is above +40°F
(+4°C).
N O T E
Go to page 2-166 for procedure
t o s t a r t e n g i n e w h e n a ir
temperature is -25° to +40°F
(-32° to +4°C.
and try again.
2. Press START switch and hold
until engine starts, but no longer
than 15 seconds.
START
SWITCH
2-164