TM 9-2350-261-10Table 2-1. Preventive Maintenance Checks and Services for Model M113A2FOVItemNo.61IntervalCrewmemberProcedureWeeklyLocationItem toCheck/ServiceRearRampandRampDoorWARNlNGHydraulic fluid is pol-sonous and can be ab-sorbed through yourskin. Wash off any hy-draulic fluid that con-tacts your skin. Readthe hydraulic fluidwarning in the front ofthis manual.Continuedb. Check ramp hydraulic fluidlevel with ramp down. Fluidmust be visible halfway up inramp hydraulic fluid level sightglass.c. Fill to halfway if fluid is notvisible at least halfway up insight glass when ramp is down.Check for leaks.d. Check for missing breathercap.Not Fully MissionCapable If:b. Fluid is not visiblehalf way up in sightglass.c. Any Class III leak.d. Breather cap ismissing.Change 2 2-121