TM 9-2350-261-10
Table 2-1. Preventive Maintenance Checks and Services for Model M113A2 FOV
Item Interval
Location
No.
Item to
Crewmember
Not Fully Mission
Check/
Procedure
Capable If:
Service
GENERATOR OPERATOR
53
After
Smoke
Genera-
tor Sys-
d. Check strainer element
tern
and clean if required.
(M1059)
e. Check fuel can lids for
leaks.
Continued
f. Check for security of fuel
f. Fuel cans cannot
cans to carrier.
be secured to carrier.
g. Check serviceability of
webbing straps.
h. Check all fuel, air and fog
h. Any leak of fuel,
oil hoses, electric cable
Class III oil, or air
assembly connectors,
mount bolts and clamps.
from any component
Ensure they are not loose,
of smoke generator
damaged, twisted, torn or
system or any elec-
leaking.
tric wire damaged.
i. Drain waste oil from drip
pan by removing and rein-
stalling plug.
Change 5 2-105