TM 9-2350-261-10
Table 2-1. Preventive Maintenance Checks and Services for Model M113A2 FOV
Item Interval
Location
Item to
Crewmember
Procedure
Not Fully Mission
No.
Check/
Capable If:
Service
GUNNER
41
After
Mortar
See TM 9-1015-215-10 to con- Fault listed in "Not
Carrier
duct PMCS for 4.2 inch, Fully Mission Capa-
(M105A2, 107-mm mortar.
ble If" column of mor-
M125A2,
tar TM.
M1064)
See TM 9-1015-200-10 to con-
duct PMCS for 81-mm mortar.
See TM 9-1015-250-10 to con-
duct PMCS for 4.7 inch,
120-mm mortar.
NOTE
Assist carrier com-
mander and driver in
performing PMCS on
carrier.
41.1 After Ammo
Check racks, door, posts
Racks,
and hinges for cracks and
Door,
breaks. Report damaged
Posts
racks, hinges, doors or
and
posts to unit maintenance.
Hinges
(M106A2,
WARNING
M125A2,
M1064)
Fuel lines may vibrate
loose or crack during
mortar firing. Fuel leaks
can cause fumes or fires
which cause serious
bodily harm or death to
personnel. if fuel leaks,
STOP FIRING. Repair
leaks or cracks, wipe up
any excess fuel before
you resume firing.
Change 5 2-83