TM 9-2350-261-10
Table 2-1. Preventive Maintenance Checks and Services for Model M113A2 FOV
Item
No.
8
Before
Location
Item to
Check/
Service
Portable
Fire Ex-
tin-
guisher
M1068 ONLY .
crewmember
Procedure
CREWMEMBER
a.
A fire can break out
any time. Personnel
could be killed or in-
jured.
Equipment
could be damaged.
Make sure both fire
extinguishers
are
ready to use before
you operate carrier.
NOTE
Manually lower ramp
before proceeding with
PMCS.
Check control seal to make
sure seal or Iockwire is not bro-
<en. Report broken seal to unit
maintenance.
b. Check for a full charge.
c. Check fire extinguisher for
security of mounting hardware.
Not Fully Mission
Capable If:
a. Extinguisher miss-
ing, seal or Iockwire
missing or broken.
b. Pressure gage in-
dicates in discharge
area, or seal is bro-
ken. Extinguisher
eels light if no gage.
Change 3
2-43
Interval