TM 9-2350-247-34REPAIR CAB DOOR — Continued 0039 00d. Pour polyurethane foam mixture into 3/4 inch (1.9 cm) diameter holes in inner door panel to produce parallel foamribbons. Distribution should be as uniform as possible. Do not pour from a height more than 36 inches (91.4 cm) tominimize density buildup and shear effects on the bond.e. Allow to cure at room temperature at least 15 minutes before moving. The rigid mass will have approximately 75percent of its final physical properties.f. Allow to cure at room temperature at least 36 hours before using. The rigid mass will have approximately 90percent of its final physical properties after 24 hours.g. Scrape off excess foam from exterior surfaces of cab door.FOLLOW-THROUGH STEPS1. Install cab door (see your -20).END OF TASK0039 00-4
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business