TM 9-2350-247-34
REPLACE POWER PLANT WIRING HARNESS (M548A1) Continued
0026 00
REMOVAL
NOTE
Tag all wires and connectors.
1.
Disconnect circuit 6 connector (1) and multiple connector (2) from battery compartment bulkhead.
2.
Remove two lock nuts (3), lock washer (4), screws (5), and clamps (6) securing power plant wiring harness (7) to top of
bracket (8) and cross-shaft (9). Discard lock nuts and lock washer.
3.
Disconnect circuit 328 lead (10) from differential oil high temperature switch.