TM 9-2350-247-34
REPLACE INSTRUMENT PANEL (M548A1) Continued
0018 00
DISCONNECT POWER WIRING HARNESS
NOTE
For proper installation, tag all electrical leads when removed.
1.
Disconnect circuit 27E lead (1) from battery generator regulator.
2.
Disconnect circuit 40 lead (2) from left instrument panel light.
3.
Disconnect circuit 27B lead (3) and circuit 33 lead (4) from coolant temperature indicator.
4.
Disconnect circuit 27A lead (5) and circuit 28 lead (6) from fuel quantity indicator.
5.
Disconnect 450 lead (7) and circuit 450B lead (8) from bilge pump switch.
0018 00-3