TM 9-2350-247-20-3REPLACE FYR-FYTER CONTROL VALVE — Continued 0527 00REMOVAL1. Loosen nut (1) that secures tube (2) to adapter (3).2. Loosen nut (4) that secures control valve (5) to cylinder (6). Remove valve.3. Cut seal wire (7). Remove wire and seal (8). Discard wire and seal.4. Pull handle (9) and remove insert (10) from handle.0527 00-2