TM 9-2350-247-20-3REPLACE TACHOMETER CABLE HOUSING AND ADAPTER (M548A1) — Continued 0520 00REMOVALNOTEIf material handling kit is installed, remove bulkhead protector (WP 0487 00).1. Disconnect tachometer cable housing (1) from tachometer drive adapter (2) on engine.2. Remove tachometer cable housing (1), four screws (3), washers (4), and clamps (5) from hull weld nuts (6).3. Pull tachometer cable housing (1) from two clips (7) on lower bulkhead panel (8).4. Pull tachometer cable housing (1) through grommet (9) located in bulkhead (10) and out of carrier.0520 00-2