TM 9-2350-247-20-1PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS), INCLUDINGLUBRICATION INSTRUCTIONS — Continued0128 00ITEMNO.INTERVALMAN-HOURITEM TO BECHECKED ORSERVICEDCREWMEMBERPROCEDUREEQUIPMENTNOT READY/AVAILABLEIF:72Semi-Annual(M548A1)1.2Pivot SteerWARNINGFireResistantHydraulic (FRH) fluid maycontain tricresyl phosphate which, if takeninternally, can produce paralysis.Hydraulic fluid may be absorbed throughthe skin. Wear long sleeves, gloves,goggles, and face shield. If FRH gets ineyes, wash them immediately and getmedical aid immediately. If FRH gets onyour skin, thoroughly wash with soap andwater. Wash hands thoroughly prior toeating or smoking. Application of thesemeasures is considered an effective controlof the hazard.CAUTIONUse only FRH or OHA hydraulic fluid. Donot mix different types of hydraulic fluids.Do not overfill.NOTEIf hydraulic fluid is contaminated, or fluidtype is changed, drain pivot steer system,(WP 0371 00).a. Remove fill plugs and check pivot steer mastercylinders every 150 hours, 1500 miles orsemi-annually. Add FRH as required to bringfluid within 1/2 to 3/4 inch from top of cylinder.For lubricant information, see Table 13, page0128 00-19.0128 00-84