TM 9-2350-247-20-1
PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS), INCLUDING
LUBRICATION INSTRUCTIONS Continued
0128 00
ITEM
NO.
INTERVAL
MAN-
HOUR
ITEM TO BE
CHECKED OR
SERVICED
CREWMEMBER
PROCEDURE
EQUIPMENT
NOT READY/
AVAILABLE
IF:
c. Check electrolyte level in all cells of batteries.
Add distilled water as needed. See TM
9-6140-200-14.
Any leaks,
loose,
damaged,
burned post,
cracked,
broken,
missing
batteries or
hardware.
d. Test specific gravity of batteries. See TM
9-6140-200-14.
Cell is below
specific
gravity.
e. Clean vent holes in cell caps. See TM
9-6140-200-14.
f. Clean terminals, posts, and bolts. See TM
9-6140-200-14.
One or more
batteries
unserviceable,
missing,
broken, or
frayed cables.
g. Tighten terminals and bolts with care to avoid
damage to batteries. Apply light coat of GAA
grease (WP 0542 00, Item 14).
One or more
batteries
unserviceable,
missing,
broken, or
frayed cables.
0128 00-42