TM 9-2350-247-10
PREVENTIVE MAINTENANCE CHECKS AND SERVICES Continued
0057 00
ITEM
NO.
INTERVAL
MAN-
HOUR
ITEM TO BE
CHECKED OR
SERVICED
CREWMEMBER
PROCEDURE
EQUIPMENT
NOT READY/
AVAILABLE
IF:
37
After
Personnel
Heater Fuel
Filter Drain
(M548A3)
DRIVER
a. Remove front cover
Any fuel leak.
b. Put a suitable container under the drain valve.
c. Push on the valve.
d. Check that fuel is clear; drain until clear.
SPRING LOADED
DRAIN VALVE
0057
00-59