5.
Remove cap from auxiliary power receptacle on both carriers.
6.
Connect slave cable to receptacle in dead carrier and to receptacle in source carrier.
7.
Start engine of source carrier. Make sure engine is running fast enough to show charging on carriers battery-generator
gauge.
NOTE
In cold weather, airbox heater of dead carrier can be turned on to heat dead carriers engine.
See WP 0013 00 or WP 0014 00.
8.
Start engine of dead carrier (WP 0013 00) for M548A1 or (WP 0014 00) for M548A3. When engine is running
smoothly, disconnect slave cable from receptacle on both carriers.
9.
Install cap on auxiliary power receptacle on both carriers.