LUBRICATION ORDER
LO 9-2350-272-12
29 September 1995
(Supersedes LO 9-2350-272-12 March 1994)
CARRIER, CARGO, TRACKED, 1 TON, M973
SMALL UNIT SUPPORT VEHICLE (SUSV)
TM 9-2350-272-10, -20, LO 9-2350-272-12 cards 1, 2, 3, 4, 5, 6, 7, 8, 9 and 10.
WARNING
lnterval (on-condition or hard time) and the related man-
hour times are based on normal operation. The man-hour
time specified is the time you need to do all the services
Dry cleaning solvent, P-D-680 "Type II" used to
prescribed for a particular interval. On-condition (OC) oil
clean parts, is potentially dangerous to personnel
sample intervals shall be applied unless changed by the Ar-
and property. Do not use near open flame or ex-
my Oil Analysis Program (AOAP) laboratory. Change the
cessive heat. Flash point of solvent is 138F
hard time interval if your lubricants are contaminated or if
(58.8C).
you are operating the equipment under adverse operating
conditions, including longer-than-usual operating hours.
Clean parts with dry cleaning solvent P-D-680, "Type II"
The hard time interval may be extended during periods of
or equivalent. Dry before lubricating.
low activity. If extended, adequate preservation precau-
tions must be taken. Hard time intervals will be applied in
Dotted arrow points indicate lubrication on both sides of
the event AOAP laboratory support is not available.
the equipment. The lowest level of maintenance authorized
to lubricate a point is indicated by one of the following sym-
On-condition (OC) AOAP Laboratory determined oil changer
bols Operator/Crow (C); and Organizational Maintenance
intervals shall be applied instead of hard time intervals such
(O).
as hourly, calendar, or mileage, unless otherwise notified.
The services will be required when directed by an Army Oil
Reporting errors and recommending improvements. You
Analysis Program (AOAP) Laboratory which has analyzed
con help improve this publication. If you find my mistakes,
the oil for serviceability.
or if you know of a way to improve the procedures, please
let us know. Mail your letter, DA Form 2028 (Recommend-
*The time specified is the time required to perform all ser-
ed Changes to Publication and Blank Forms) direct to: US
vices at the particular interval (on-condition or hard times).
Army Tank-automotive and Armaments Command,
Relubricate after cleaning, fording or swimming. Times in-
ATTN: AMSTA-IM-MMAA, Warren, MI 49397-5000. A
dicated in the total man-hours chart does not include time
reply will be furnished to you.
to access equipment.
*TOTAL MAN-HOURS
MAN-HR
INTERVAL
D
0.3
2.2
M
3.2
Q
S
2.8
A
2.4
B
0.8
TA259915
Approved for public release; distribution is unlimited.
CARD 1 OF 10
LO 9-2350-272-12