9.
10.
11.
12.
13.
14.
Install grommet (16) in fan assembly housing (9). Feed four electrical leads (19) and ground wire lead (13)
through grommet (16).
Install four screws (20) and washers (12) to front of fan assembly housing (9). Using wire-twist pliers, secure
four screws (20) with new nonelectrical wire (11).
Install noise fitter (5) on fan assembly housing (9) ground wire lead (13), and secure with four screws (14) and
washers (15). Using wire-twist pliers, secure four screws (14) with new nonelectrical wire (11).
Install four electrical leads (19) to noise fitter (5) with four nuts (18) and new Iockwashers (17).
Install cover (6) on noise filter (5) and secure with two nuts (7) and new Iockwashers (8).
Install two washers (10), shaft key (4), and impeller (3) on front of fan assembly housing (9) and secure with
nut (1) and washer (2).