8-5. TRACK ADJUSTER REPAIR (continued).
2.
3.
4.
5.
6.
7.
8.
b.
1.
Remove bleeder plug (9) and bleeder body (11) from cylinder (1).
Remove nut (5) and piston (6) from cylinder (1).
Remove two retainers (7) and preformed packing (8) from piston (6). Discard retainers and preformed
packing.
Remove scraper (3) and preformed packing (4) from nut (5). Discard scraper and preformed packing.
Remove lubrication fitting (10) from cylinder (1).
Remove cylinder (1) from vise.
NOTE
Perform step 8 only if bearings fail inspection.
Using arbor press, remove two bearings (2) from end of cylinder (1) and/or piston (6). Discard bearings.
CLEANING AND INSPECTION
Inspect two bearings (2) (refer to TM 9-214).
WARNING
2.
c.
Drycleaning solvent P-D-680 is toxic and flammable. Always wear protective goggles
and gloves, and use in a well-ventilated area. Avoid contact with skin, eyes, and
clothes, and DO NOT breathe vapors. DO NOT use near open flame or excessive heat.
Clean all parts using drycleaning solvent.
ASSEMBLY
NOTE
Perform step 1 only if bearings were removed.
1.
Use arbor press to install two new bearings (2) in cylinder (1) and/or piston (6).
2.
Coat inside of cylinder (1) with grease.
3.
Place cylinder (1) in vise.
4.
Install lubrication fitting (10) in cylinder (1).