6-2. RECTIFIER MAINTENANCE (continued).
10.
Install three electrical leads (15) and two electrical leads (14) on connector (13). Install electrical lead (6) and
two electrical leads (8) on connector (21).
11.
Thread two electrical leads (14) through housing (10), and connect two electrical leads (14) to connector (21).
WARNING
Sealing compound can bum easily, can give off harmful vapors, and is harmful to skin
and clothing. To avoid injury or death, keep sealing compound away from open fire
and use it in a well-ventilated area. if sealing compound gets on skin or clothing, wash
immediately with soap and water.
12.
Apply sealing compound to threads of four screws (1 2). Install connector (1 3) and new gasket (23) on housing
(10) with four screws (12).
13.
Apply sealing compound to threads of four screws (22). Install connector (21) and new gasket (20) on housing
(10) with four screws (22).
1 4.
Bend top three electrical leads (15) to 90 degrees.
15.
Remove three Iockwashers (1 6), washers (1 7), and screws (18) from housing (10). Install three Iockwashers
(16), washers (17), electrical leads (15), electrical leads (19), and screws (18) on housing (10).
6-10
|