TM   9-2350-287-20-2 13-2. TOWING PINTLE REPAIR (continued). 5. Remove pin (10), latch (16), and spring (18) from pintle body (6). 6. Remove pin (17) from latch (16). 7. Remove fitting (9) from pin (10). 8. Remove fitting(19) from bracket (3). c. CLEANING AND INSPECTION WARNING Drycleaning  solvent  P-D-680  is  toxic  and  flammable.  Always  wear  protective  goggles and gloves, and use only in a well-ventilated area. Avoid contact with skin, eyes, and clothes, and DO NOT use near open flame or excessive heat. 1. Clean all parts with drycleaning solvent and rag. Allow parts to air-dry. 2. Measure spring (18). If spring is less than 3 inches (7.6 cm) long, replace it. 3. Clean grease holes in two pins (10 and 13) and bracket (3). 13-3